UT-207B Clamp Meter

KSh10,499.00

Product Specifications

  • Product: Unit T-(UT-207B) Clamp Meter 1000AH
  • Model: UT-207B / UT207B
  • Type: Digital clamp meter
  • Maximum AC current: 1000A
  • Maximum DC current: 1000A
  • Voltage measurement: AC and DC
  • Display: 6000 counts
  • Jaw opening: Approximately 42mm
  • Additional functions: Resistance, capacitance, frequency, duty cycle, continuity, diode testing, NCV, inrush current, LPF and LoZ
  • Power supply: 3 × 1.5V AAA batteries, according to the UT207B manual
  • Safety rating: Manufacturer-listed CAT III 1000V / CAT IV 600V; verify the actual unit markings
  • Recommended users: Electricians, technicians and maintenance professionals
Order on WhatsApp
Category:
Description

UT-207B Clamp Meter

The UT-207B Clamp Meter is a versatile electrical testing instrument designed to help electricians, technicians and maintenance professionals measure electrical current and check important circuit parameters. Its clamp-style design allows current measurement around a single conductor without disconnecting it, when used correctly and within the meter’s rated limits.

The Unit T-(UT-207B) Clamp Meter is listed for customers looking for a practical tool for electrical installation, troubleshooting and routine maintenance. The UT-207B model in the UNI-T UT200 series is specified as a 1000A True RMS digital clamp meter. Please verify the brand marking on the actual product before ordering, as the name supplied for this listing uses “Unit T.”

Why Choose the UT-207B Clamp Meter?

A good clamp meter helps professionals investigate electrical problems efficiently. Instead of cutting into a conductor to measure current, the user opens the clamp jaws and places them around one conductor. This makes the instrument useful for many inspection and maintenance tasks.

The UT-207B model offers several measurement and diagnostic functions according to the manufacturer’s UT200-series documentation. These include AC and DC current measurement, voltage measurement, resistance, capacitance and other functions. Exact operating limits depend on the selected function and the meter’s specifications.

Measure AC and DC Current

The UT-207B is specified for current measurements up to 1000A AC and 1000A DC. This can make it useful for checking suitable electrical circuits, equipment and power systems. Always select the correct measurement mode and confirm that the expected current is within the instrument’s rated range.

When measuring current with the clamp, enclose only one conductor. Clamping around both the live and return conductors together can cause their magnetic fields to cancel and produce an incorrect reading.

Check Voltage and Circuit Conditions

The meter supports AC and DC voltage measurement. These functions can help qualified users investigate electrical supplies, compare readings with expected values and identify possible circuit issues.

Voltage measurement uses the test leads rather than the clamp jaws. Connect the leads only to the correct terminals, select the appropriate function and observe the maximum voltage and safety-category ratings printed on the actual meter and stated in its manual.

Resistance, Capacitance and Continuity Checks

Resistance and capacitance measurements can assist with selected electrical troubleshooting tasks. Continuity and diode testing are also listed among the UT-207B’s functions in the UT200-series documentation.

Before performing resistance, capacitance, continuity or diode tests, isolate the circuit from its power source and verify that it is de-energised. Discharge capacitors safely before testing them. Never use a resistance or continuity mode on an energised circuit.

True RMS Measurement

The UT-207B is described by UNI-T as a True RMS digital clamp meter. True RMS measurement can be useful when measuring certain AC waveforms that are not simple sine waves, provided the signal remains within the instrument’s specified frequency and measurement limits.

For accurate readings, follow the instructions for the selected mode and use the instrument within its published specifications.

Key Features of the UT-207B Clamp Meter

  • Current measurement: Rated for up to 1000A AC and 1000A DC in the UT-207B specification.
  • Voltage measurement: AC and DC voltage functions.
  • True RMS: Supports measurement of suitable AC waveforms within the specified limits.
  • Digital display: 6000-count display for reading measured values.
  • Resistance and capacitance: Useful for selected diagnostic tasks.
  • Frequency and duty cycle: Functions available for suitable measurements.
  • Non-contact voltage detection (NCV): Helps identify the possible presence of AC voltage without direct electrical contact; it does not replace verification with an appropriate test method.
  • Low-pass filter and low-impedance modes: Available for specified voltage measurements on this model.
  • Inrush current measurement: Helps capture certain starting-current events when used according to the manual.
  • Automatic power-off and backlight: Features listed in the UT200-series documentation.

Features can vary between visually similar clamp meters. Check the label and manual for the unit supplied before relying on any particular function.

UT-207B Clamp Meter Specifications

The following details are based on the manufacturer’s documentation for the UNI-T UT207B. Confirm that the product being sold matches this model.

  • Product name: Unit T-(UT-207B) Clamp Meter 1000AH
  • Model identifier: UT-207B / UT207B
  • Instrument type: Digital clamp meter
  • Current range: Up to 1000A AC and 1000A DC
  • Voltage functions: AC and DC voltage measurement
  • Display: 6000 counts
  • Clamp jaw opening: Approximately 42mm
  • Additional functions: Resistance, capacitance, frequency, duty cycle, continuity, diode, NCV, inrush current, LPF and LoZ modes
  • Power: Three 1.5V AAA batteries according to the UT200-series manual
  • Safety category: Manufacturer documentation lists CAT III 1000V / CAT IV 600V; verify the markings on the actual unit
  • Brand: Confirm the brand printed on the product before purchase

The “1000AH” wording in the supplied product title should not be interpreted as a battery capacity. Clamp-meter current ratings are expressed in amperes (A). The model’s published maximum current rating is 1000A, not 1000Ah.

Where Can You Use the UT-207B Clamp Meter?

Electrical Installation and Maintenance

Electricians can use an appropriate clamp meter to measure current on compatible circuits and investigate electrical installation issues. Voltage and continuity functions can support other checks when the circuit condition and selected mode permit them.

Equipment Troubleshooting

Maintenance technicians may use the meter when investigating motors, electrical panels and other equipment. Measurements can help compare actual readings with equipment specifications and identify conditions that need further inspection.

Workshop and Commercial Maintenance

Workshops, commercial buildings and facilities teams often need reliable electrical testing equipment for routine servicing. A multi-function meter can reduce the need to carry several separate instruments for basic diagnostic work.

Technical Training

Under appropriate supervision, the UT-207B can support demonstrations of electrical measurement principles. Learners should be trained in safe isolation, correct meter selection, measurement categories and the limitations of non-contact voltage detection before working with electrical circuits.

How to Use a Clamp Meter Correctly

  1. Inspect the meter. Check the casing, clamp jaws, test leads, probes and display for visible damage. Do not use damaged equipment.
  2. Read the manual. Confirm the correct mode, measurement range, terminal connections and safety limits before testing.
  3. Select the required function. Choose the appropriate AC or DC current mode for clamp measurements, or the correct voltage mode for test-lead measurements.
  4. Clamp around one conductor. Open the jaws and position them around a single conductor. Close the jaws fully and, where instructed, centre the conductor within them.
  5. Read and interpret the display. Compare the reading with the expected operating values and the equipment’s specifications.
  6. Use test leads correctly. For voltage or other lead-based tests, connect the leads to the specified terminals and observe the meter’s rated limits.
  7. Finish safely. Remove the meter from the test point, switch it off when appropriate and store it in a dry, protected place.

Electrical testing can expose users to dangerous voltages and arc-flash hazards. Only competent users should carry out work on electrical systems. Follow local requirements, use appropriate protective equipment and isolate circuits whenever the task allows it.

Maintenance Tips for Your UT-207B Clamp Meter

Keep the instrument clean and dry. Wipe the casing with a soft cloth, and avoid solvents or liquids that could damage the meter. Store the unit away from excessive heat, moisture, dust and impact.

Inspect the clamp-jaw surfaces regularly. Dirt or damage can affect operation. Check test leads and probes for cracked insulation, exposed metal or loose connections before use. Replace damaged accessories with suitable, correctly rated replacements.

Pay attention to the low-battery indicator and replace batteries according to the manual. Remove batteries before long-term storage if the manufacturer recommends it. Do not open the instrument or attempt repairs unless qualified to do so.

For dependable results, observe the manufacturer’s calibration and inspection recommendations. A reading should never be treated as proof that a circuit is safe to touch unless the appropriate isolation and verification procedure has been completed.

Buy the UT-207B Clamp Meter from Pejam Tools Kenya

Looking for a clamp meter for electrical testing and maintenance? The Unit T-(UT-207B) Clamp Meter 1000AH listing is intended to help you identify the UT-207B model and its main measurement capabilities.

Before placing an order, confirm the exact brand, supplied accessories, condition, availability and specifications with Pejam Tools Kenya. If you need help choosing a suitable measuring instrument, browse our shop for tools and equipment or visit the Pejam Tools Kenya homepage.

For further technical details, consult the official UNI-T UT200 series product page and the manufacturer’s UT207B user manual. For general information about electrical safety in the workplace, refer to the UK Health and Safety Executive’s electrical safety guidance.

Frequently Asked Questions

What does UT-207B mean?

UT-207B is the model identifier used for the UT207B digital clamp meter in UNI-T’s UT200 series. Check the actual product label to confirm that the unit matches the published specifications.

Can the UT-207B measure up to 1000A?

The manufacturer’s specifications list AC and DC current measurement up to 1000A for the UT207B. The permitted range depends on the selected function and the conditions specified in the manual. Never exceed the instrument’s ratings.

Is 1000AH the same as 1000A?

No. Ampere (A) is a unit of electric current, while ampere-hour (Ah) is a unit of electric charge capacity. The supplied product title says “1000AH,” but the UT207B clamp meter is specified as a 1000A instrument.

Does the UT-207B measure voltage?

Yes. The manufacturer lists AC and DC voltage measurement. Use the test leads, correct function and appropriate safety procedures, and never exceed the marked voltage limits.

Is this clamp meter suitable for beginners?

It may be used for learning under competent supervision. Electrical measurement can be hazardous, so anyone unfamiliar with electrical testing should learn the correct procedures and read the manual before using the instrument.

What should I confirm before ordering?

Confirm the model and brand printed on the meter, measurement functions, included accessories, product condition, warranty and current availability. These checks help ensure that you receive the correct instrument for your work.

UT-207B Clamp Meter 1000A

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “UT-207B Clamp Meter”

Your email address will not be published. Required fields are marked *